Susol VCB for ANSI type

Susol Vacuum Circuit Breaker for ANSI type

Vacuum Circuit Breaker, VCB is installed in the medium voltage distribution lines to protect life and load equipment. In case of accidents such as over current, short circuit and ground fault current, VCB works by interrupting the circuit through the inner Vacuum Interrupter which is acted by signal from the outside separate relay.

Features

More Info

Download

[et_pb_ds_breadcrumbs _builder_version=”4.8.2″ _module_preset=”default”][/et_pb_ds_breadcrumbs]

Features

Susol VCB responds.


– customer needs for the breakers with high interrupting capacity and large

current due to the integration and increase of the load capacity.
– worldwide trend of diversification in the medium voltage distribution lines.
– increase of the reliability for the temperature characteristics of circuit

breakers.

Premium-type products to improve convenience and reliability of medium voltage switchgear configuration.


– full line-up modeling to the high interrupting capacity and large current.
– main structure with high reliability application.

– a variety of accessories and ability to maximize.

Suitable for use as the main circuit breaker to protect key installations in the places such as device industry, power plants, high-rise buildings, large ships.

More Info

4.76/15/27kV (UVL-05/15/27)

Rated short-time (to withstand current ): 4sec Rated operating sequence: O-0.3s-CO-15s-CO Various cradle: Ha, Hb type
CB Compartment for MCSG available

A variety of control power

  • –  DC 24~30V, DC 48~60V, DC 110V, DC 125V, DC 220V
  • –  AC 48V, AC 100~130V, AC 220~250V

    A variety of accessories

  • –  VCB part: Charge switch, UVT, Secondary trip coil, Latch checking

    switch, Position switch, Locking magnet, Plug interlock, Key lock, Button cover, Button padlock, Padlock (H type Door interlock), MOC

  • –  Cradle part: MOC (Mechanical Operated Cell switch), TOC (Truck Operated Cell switch), Temperature sensor, Earthing switch & accessaries, Door, Door interlock, Door emergency button
  • –  Others: Racking in/out handle, UVT Time delay controller, CTD (Condensor Trip Device),

    Temperature module
    Disconnected/Test/Connected Automatic Position Indicator Standards and certification

    – IEEE Std C37.09, ANSI C37.54, UL Listed & CSA

4.76/15kV (VH-05/15)

Rated short-time (to withstand current ): 2sec Rated operating sequence: O-0.3s-CO-3min-CO Various cradle: H type
CB Compartment for MCSG available

A variety of control power

  • –  DC 48V, DC 110V, DC 125V, DC 220~250V
  • –  AC 48V, AC 110V, AC220V

    A variety of accessories

  • –  VCB part: Charge switch, UVT, Secondary trip coil, Latch checking

    switch, Position switch, Locking magnet, Plug interlock, Key lock, Button cover, Button padlock, Padlock (H type Door interlock), MOC

  • –  Cradle part: MOC (Mechanical Operated Cell switch), TOC (Truck Operated Cell switch), Temperature sensor, Earthing switch & accessaries, Door, Door interlock, Door emergency button
  • –  Others: Racking in/out handle, UVT Time delay controller, CTD (Condensor Trip Device), Temperature module

    Disconnected/Test/Connected Automatic Position Indicator Standards and certification

    – IEEE Std C37.09

38kV (UVH-38)

Rated short-time (to withstand current ): 4sec Rated operating sequence: O-0.3s-CO-15s-CO Various cradle: H type
CB Compartment for MCSG available

A variety of control power
– DC 48V, DC 110V, DC 125V, DC 220~250V – AC 48V, AC 110V, AC220V

A variety of accessories

 

VCB part: Charge switch, UVT, Secondary trip coil, Latch checking switch, Position switch, Locking magnet, Plug interlock, Key lock,

Button cover, Button padlock, Padlock (H type Door interlock), MOC Cradle part: MOC (Mechanical Operated Cell switch), TOC (Truck

Operated Cell switch), Temperature sensor, Earthing switch &

accessaries, Door, Door interlock, Door emergency button Others: Racking in/out handle, UVT Time delay controller, CTD

(Condensor Trip Device), Temperature module Disconnected/Test/Connected Automatic Position Indicator Standards and certification

– IEEE Std C37.09

Downloads

30 documents
Susol VCB for ANSI type_UL_#13

CIRCUIT BREAKERS AND METAL-CLAD SWITCHGEAR OVER 1000 VOLTS, Medium Voltage Metal Clad Switchgear over 1000V, type Solution Power S5/15 2H UL

Susol VCB for ANSI type_UL_#9

Medium Voltage Metal Clad Switchgear over 1000V, type Solution Power S5/15 UL

Susol VCB for ANSI type_UL_#10

Medium Voltage Metal Clad Switchgear over 1000V, type Solution Power S5/15 UL

Susol VCB for ANSI type_UL_#11

DLAH2 – Circuit Breakers and Metal-clad Switchgear Over 1000 Volts – Component, UVCM_UVCH Type, Compartment_Cradle

Susol VCB for ANSI type_UL_#12

DLAH – Circuit Breakers and Metal-clad Switchgear Over 1000 Volts, UCGT Type, Ground and Test Device

VCB_UL_#4

USL, CNL – Medium Voltage Metal Clad Switchgear over 1000V, type Solution Power S15

VCB_UL_#5

USL, CNL – Medium Voltage Metal Clad Switchgear over 1000V, type Solution Power S5/15 2H UL

VCB_UL_#6

Medium Voltage Metal Clad Switchgear over 1000V, type Solution Power S5/15 1H UL

[VCB] Susol VCB (UL) 15kV 31.5kA 1200 3D STP
[VCB] Susol VCB (UL) VH 15kV 30_40kA 1200 3D STP
VCB_UL_#7

USC – Medium Voltage Metal Clad Switchgear as Arc Resistant, type Solution Power S5/15 2H UL

VCB_UL_#8

Medium Voltage Metal Clad Switchgear as Arc Resistant, type Solution Power S5/15 1H UL

VCB_UL_#9

CIRCUIT BREAKERS AND METAL-CLAD SWITCHGEAR OVER 1000 VOLTS : Grounding and Testing Device, Cat. Nos. UVGT, followed by “-”, followed by 05 or 15, followed by Ms, followed by 25 or 32, followed by U, followed by 12 or 20, “-”, followed by A, may be followed by any combination of A, B, C, D.

Susol VCB for ANSI type_UL_#14

USR, CNR – Component – Medium Voltage Earthing Switch. Cat. Nos. VES, followed by “-”, followed by 05 or 15, followed by H, followed by “-”, followed by 25 or 32, followed by A or B, followed by 12 or 20, followed by “-”, followed by A1, A2 or A4.

VCB_UL_#10

COMPONENT – CIRCUIT BREAKERS AND METAL-CLAD SWITCHGEAR OVER 1000 VOLTS : USR, CNR – Component – Medium Voltage Metal-Clad Assemblies. Truck for PT/CPT, Cat. Nos. UPTR, followed by “-”, followed by 05 or 15, followed by PY, PD, CP, PS, PA or NPA, USR, CNR – Component – Medium Voltage Metal-Clad Assemblies. Cradle for PT/CPT Cat. Nos. UPCL, followed by “-”, followed by 05 or 15, followed by A or B, followed by 15, followed by A, B or C, USR, CNR – Component – Medium Voltage Metal-Clad Assemblies. Compartments for PT, Cat. Nos. UPCL, followed by “-”, followed by 05 or 15, followed by AL, AM, AF, AE, BC, BF, BE, NAL, NAM, NAF or NAE, followed by 25 or 32, followed by A, followed by 12 or 20.

Susol VCB for ANSI type_UL_#15

CIRCUIT BREAKERS AND METAL-CLAD SWITCHGEAR OVER 1000 VOLTS : Grounding and Testing Device, Cat. Nos. UVGT, followed by “-”, followed by 05 or 15, followed by Ms, followed by 25 or 32, followed by A, B, R or S, followed by 12 or 20, “-”, followed by A, may be followed by any combination of A, B, C, D.

VCB_UL_#11

COMPONENT – ACCESSORIES FOR USE IN CIRCUIT BREAKERS AND METAL-CLAD SWITCHGEAR OVER 1000 VOLTS : Bus Support Insulator, Cat. No. GDW-20A15, Through Bushing, Cat. No. DWB-2020LS

[VCB] ANSI/IEEE VH-515kV up to 3000A VCB with Cradles (DWG)
[TEST REPORT] UVL-15P25A12,15kV 25kA 1200A_VCB, Seismic Test
[VCB] Susol VCB (UL) Outline Drawing 2D DWG
[VCB] Susol VCB (UL) Catalog Outline Drawing List 2D DWG
30 documents